CT4Harmonization-Multicentric
Anthropomorphic 3D-printed CT phantom (thorax, liver, and test patterns) with two liver cysts, a metastasis, and a hemangioma, plus ground-truth liver-lesion masks, for scanner harmonization
Open the source page ↗ See it in the directory
At a glance
- What it is
- Anthropomorphic 3D-printed CT phantom (thorax, liver, and test patterns) with two liver cysts, a metastasis, and a hemangioma, plus ground-truth liver-lesion masks, for scanner harmonization
- Area
- Body
- Modality
- CT
- Format
- DICOM
- Size
- TCIA Version 2 table, updated 2026-11-20: 1 subject, 1,378 studies, 2,756 series, 467,224 images, 252.38 GB (DICOM CT and DICOM SEG). The methods text says 649 CT scans on 13 scanners from 4 manufacturers at 8 institutions were reconstructed into 1,378 CT series. The abstract instead says 268 image series at a 10 mGy dose plus an additional 1,378 image series at additional doses. The linked code repository describes the same 1,378 CT image series from 649 scans.
- Normals included
- No
- License
- CC BY 4.0
- Commercial use
- Allowed by the license, with its attribution terms
- Access
- Open download, no account
- Status
- Verified: source page reviewed by Hounsfield Lab
- Added
- 2026-11-25
- Last checked
- 2026-11-25
- Source
- www.cancerimagingarchive.net/collection/ct4harmonization-multicentric/
How to access
Open the collection page and use the Download control in the Version 2 Data Access table. The page says download requires the TCIA Data Retriever. A public CC BY 4.0 row does not need an application. Read the Citations & Data Usage Policy tab before use. Version 2 was updated 2026-11-20. Data DOI https://doi.org/10.7937/m0pb-bh69 . Preprint https://doi.org/10.48550/ARXIV.2507.01539 . Code for resampling and registration is at https://github.com/medgift/Harmonization-Dataset . The collection page also links https://github.com/QA4IQI/qa4iqi.github.io for loading the raw DICOM.
Limitations
Physical phantom, not patients, so there is no protected health information and no normal human subjects. For scanner harmonization and robustness benchmarking, not clinical diagnosis. Very large download (252.38 GB). Version 2 (2026-11-20) corrected two issues: Center H2 liver segmentations (100 series) were misaligned with the H2 CT images and were regenerated to match that geometry (the H2 CT images were not changed), and missing CT slices were restored in three series (B2_14_FBP#05, 1 slice; D1_1_DL#03, 1 slice; H1_6_IR#04, 6 slices), so each of those series is now complete at 343 slices. Series instance UIDs were changed. Study instance UIDs were not. The Data Access table (1,378 studies and 2,756 series) does not match the methods sentence of 1,378 series from 649 scans, or the abstract's 268 plus 1,378 image series. DICOM files were not preprocessed, so spacing and position still differ by scanner. Scans were repeated at 1, 3, 6, 10, and 14 mGy, with iterative reconstruction, filtered back projection, and, on two scanners, deep-learning reconstruction.
Citation required?
Yes. Cite Amirian, M., Bach, M., Jimenez del Toro, O., Aberle, C., Schaer, R., Andrearczyk, V., Maestrati, J., Flouris, K., Obmann, M., Dromain, C., Dufour, B., Poletti, P., von Tengg-Kobligk, H., Alkadhi, H., Konukoglu, E., Müller, H., Stieltjes, B., Depeursinge, A. (2025). A Multi-Centric Anthropomorphic 3D CT Phantom-Based Benchmark Dataset for Harmonization (CT4Harmonization-Multicentric) (Version 2) [dataset]. The Cancer Imaging Archive. https://doi.org/10.7937/m0pb-bh69 . Follow the TCIA Data Usage Policy. The page's publication citation is Amirian, M., Bach, M., Jimenez-del-Toro, O., Aberle, C., Schaer, R., Andrearczyk, V., Maestrati, J.-F., Asiain, M. M., Flouris, K., Obmann, M., Dromain, C., Dufour, B., Poletti, P.-A. A., von Tengg-Kobligk, H., Hügli, R., Kretzschmar, M., Alkadhi, H., Konukoglu, E., Müller, H., Stieltjes, B., Depeursinge, A. (2025). A Multi-Centric Anthropomorphic 3D CT Phantom-Based Benchmark Dataset for Harmonization (Version 1). arXiv. https://doi.org/10.48550/ARXIV.2507.01539 .
Related open-source tools
- TotalSegmentator: Segments more than 100 anatomical structures in CT and MR
- NV-Segment-CT: CT segmentation built from MONAI VISTA3D: 117 structures automatically, or 132 promptable by point or class. Research use only, not for clinical care. Needs a CUDA GPU; weights are about 872 MB
- IMPACT-Seg: Segments 126 anatomical structures (organs, lung lobes, heart chambers and great vessels, every vertebra and rib by level, bones, trunk muscles and head-and-neck organs at risk) with the same network on planning CT, cone-beam CT and MRI, with no modality flag; 2.5D and 3D residual-encoder U-Nets (five folds each) plus a coarse body-region model, trained on 8,290 harmonized CT, real and simulated CBCT and MRI volumes; its decoder features also serve as a multimodal registration similarity. Runs as KonfAI apps (pip install impact_seg_konfai) or a 3D Slicer extension
- Merlin: 3D vision-language model for CT that uses structured EHR and report supervision
- Pillar-0 (finetune code + HF weights): Open 3D radiology foundation model; finetuning framework, weights on Hugging Face
- nnU-Net: Self-configuring segmentation framework
- pydicom: Read, modify and write DICOM files in Python
More body datasets
- AMOS (abdominal multi-organ segmentation): CT, MR · CC BY 4.0
- C4KC-KiTS: CT · CC BY 3.0
- Colorectal-Liver-Metastases: CT · CC BY 4.0
- CT Colonography: CT · CC BY 3.0 and CC BY 4.0 (see the file table)
- CT-ORG: CT · CC BY 3.0
- Healthy-Total-Body-CTs: CT · NIH Controlled Data Access Policy (CT images); CC BY 4.0 (organ segmentations and demographics)
Hounsfield Lab links to the source and does not host images. The license and access summary reflects the source page on the last-checked date; terms can change, so read the source before you download. Not legal advice.