LDCT-and-Projection-data

Non-contrast head CT for acute cognitive or motor deficit, low-dose non-contrast chest CT for lung-nodule screening, and contrast-enhanced abdominal CT for liver metastases. Pathology annotations and patient age are in the clinical spreadsheet.

Check licenseVerifiedCredentialed DUA
AREANeuro, Chest, BodyMODCTFORMATDICOMNORMALSPartialLICChest, liver, and phantom images CC BY 4.0; head images under the NIH Controlled Data Access PolicyCHECKED2026-11-11

Open the source page ↗ See it in the directory

At a glance

What it is
Non-contrast head CT for acute cognitive or motor deficit, low-dose non-contrast chest CT for lung-nodule screening, and contrast-enhanced abdominal CT for liver metastases. Pathology annotations and patient age are in the clinical spreadsheet.
Area
Neuro, Chest, Body
Modality
CT
Format
DICOM
Size
299 subjects; about 1.29 TB. Version 8 download table: chest 256.81 GB (99 subjects), liver 604.12 GB (100 subjects), head 462.77 GB (99 subjects), phantom 1.8 GB (1 subject). The collection text still describes 100 chest scans.
Normals included
Partial (mixed or unlabeled)
License
Chest, liver, and phantom images CC BY 4.0; head images under the NIH Controlled Data Access Policy
Commercial use
Mixed or unclear; check the source
Access
Credentialed access under a data-use agreement
Status
Verified: source page reviewed by Hounsfield Lab
Added
2026-11-11
Last checked
2026-11-11
Source
www.cancerimagingarchive.net/collection/ldct-and-projection-data/

How to access

Head images can reconstruct a face, so they are not an open download. Follow the NIH Controlled Data Access Policy link on the collection page and complete that request before using the head manifest with the TCIA Data Retriever. Chest, liver, and phantom images, and the clinical spreadsheet, are public Creative Commons rows. Open the collection page and use the download control in the Data Access table (TCIA Data Retriever). Those rows do not need an application. Read the Citations & Data Usage Policy tab before use.

Limitations

Do not assume the whole collection is CC BY. Chest, liver, and phantom images are CC BY 4.0, which allows commercial use with attribution. Head images are under the NIH Controlled Data Access Policy because a face could be reconstructed. The clinical spreadsheet is CC BY 4.0. The Matlab DICOM-CT-PD dictionary and reader on the same table are CC BY 3.0. Version 8 (updated 2026-11-09) corrected 8 chest lesion coordinates in the clinical spreadsheet and clarified the manual; the snapshots were not changed. Very large. Built for reconstruction and denoising research. Each case includes DICOM images and DICOM-CT-PD projection data at the routine dose and at a simulated lower dose (25% for head and abdomen, 10% for chest). Reconstructions are filtered back projection only. The page includes low-dose reconstructed images for the Siemens SOMATOM Definition Flash cases. Scanners named on the page are the Siemens SOMATOM Definition Flash and the GE Lightspeed VCT. These are mixed clinical exams, not a healthy-volunteer set. Check the clinical spreadsheet before treating a case as normal.

Citation required?

Yes. McCollough C, Chen B, Holmes III D, Duan X, Yu Z, Yu L, Leng S, Fletcher J (2020). Low Dose CT Image and Projection Data (LDCT-and-Projection-data) (Version 8). The Cancer Imaging Archive. https://doi.org/10.7937/9npb-2637 . Also cite Moen TR et al., Medical Physics 2020, https://doi.org/10.1002/mp.14594 . Acknowledge NIBIB grants EB017095 and EB017185. Follow the TCIA Data Usage Policy.

Related open-source tools

More neuro datasets

Hounsfield Lab links to the source and does not host images. The license and access summary reflects the source page on the last-checked date; terms can change, so read the source before you download. Not legal advice.

← All DICOM datasets